Generator DSG410
Characteristics
| Property | |
|---|---|
| Model name | DSG410 |
| Controller Unit | DSE |
| Peak Power | 451 KVA - 360.8 KW |
| Prime Power | 410 KVA - 328 KW |
| Tension | 400 V |
| Flow | 592 A |
| Cos θ | 0.8 |
| Frequency | 50 Hz |
| Phases | 3+N |
| RPM | 1500 RPM |
| Alternator Brand | STAMFORD |
| Alternator Model | S4L1D-F / S4L1D-G |
| Noise level (7 m) | 69 dB |
| Weight | 4700 Kg |
| Length | 4500 mm |
| Width | 2030 mm |
| Height | 2410 mm |
| Battery | 24 V |
| Tank (standard) | 700 L |
| Degree of protection | IP23 |
| Insulation class | H |
Options
- Tank capacity This model comes with a 700 L tank. Do you wish to order it with a different tank capacity? No problem!
- Connections Would you like special or extra connections? No problem.
- Brand of the engine can be freely selected. We are happy to help you make this choice.
- Noise level if necessary, can be additionally suppressed by customizing a cabinet.
- Controller Unit model depending on desired functions: auto start, time schedule, remote monitoring and control, cascade ...
Engines
| Brand | Model | Emission standard | Cylinders | Content | Type | Cooling | Power | Injection | Management | Consumption (50 / 75 / 100 %) | |
|---|---|---|---|---|---|---|---|---|---|---|---|
Volvo | TAD1344GE | Stage II | 6 | 12780 CC | Turbocharged | Water | 354 KW | Direct | Electronic | 41,7* / 61,3* / 80,9* L/u | |
Volvo | TAD1355GE | Stage IIIA | 6 | 12780 CC | Turbocharged | Water | 355 KW | Direct | Electronic | 47** / 64** / 82** L/u | |
* Converted from the specific fuel consumption (g/kWh) stated by the engine manufacturer.
** Read from the consumption curve of the engine manufacturer; indicative value.

Volvo